97超碰人人爱香蕉精品丨香蕉依人丨日韩人妻无码免费视频一二区丨国产欧美精品aaaaa久久丨久久草在线精品丨国产二区一区丨精精国产xxxx视频在线观看丨日日碰狠狠添天天爽五月婷丨黄色高清免费丨精品不卡在线丨国产成人av乱码免费观看丨一本久久久丨精品国产午夜理论片不卡精品丨www色中色丨五十岁熟韵母乱视国产丨国产操女人丨亚洲国产香蕉碰碰人人丨亚洲第一精品网站丨无码8090精品久久一区丨a天堂在线观看丨一区二区在线看丨牲欲强的熟妇农村老妇女丨日韩欧美猛交xxxxx无码丨国产免费专区丨奇米影视888狠狠狠

欄目導航

avigation

網站首頁>產品展示 > > > G2258AG2258A 安捷倫自動進樣器

G2258A 安捷倫自動進樣器

發布時間:2024-06-13

訪問次數:3521

公司地址:廣州市天河區天河北路僑林街47號中旅商務大廈東塔25E

產品價格:來電咨詢

產品詳情在線留言
品牌Agilent/安捷倫

G2258A 1100/1200系列雙定量環自動進樣器(二手),產品處于嶄新狀態,能正常使用。

This listing is for an Agilent 1200 Series G2258A DLA Dual Loop Auto Sampler.

This unit has been fully refurbished and is in excellent condition.

Serial number is DE63055145

For High Sample Throughput

The Agilent 1200 Series dual loop autosampler is designed for flexible sample handling for both analytical (10 mL/min flow rate) to preparative scale purification (100 mL/min flow rate). It can be upgraded from non-thermostatted to thermostatted version by adding the Agilent 1200 Series thermostat.

Features:

  • Flexible injection volumes with 'fixed-dual loop' concept
  • Injection of volumes > 5 mL possible. Multi-draw function that allows larger sample volumes.
  • Lowest carry over by external and internal needle wash mechanism
  • Injection from variety of sample containers (vials and wellplates)
  • Optional Peltier temperature control from 4 to 40 °C for protection of thermally-labile samples
 
Specifications 

Performance Specifications 1200 Series Dual Loop Autosampler

Injection modesPartial loop filling
Complete loop filling
Injection range0.1 - 5000 µL in 0.1 µL increments
Recommended injection range 10 - 5000 µL
Loop sizeMax. loop size 5 ml (selectable range: 5 µL - 50000 µL)
Area precision
Complete loop fill
Typically < 0.5% RSD,(50 µL loop, overfill factor 3 or greater)
Area precision
Partial loop fill
Typically < 1.0% RSD,(5000 µL loop, 1000µL injection volume, draw/eject speed 20 mL/min)
Sample viscosity range0.2 - 5 cp
Sample capacity2 well-plates (96 and 384) plus 10 additional 2-mL vials
108 x 2-mL vials in 2 x 54 vial plate plus 10 additional 2-mL vials
30 x 6-mL vials in 2 x 15 vial plate plus 10 additional 2-mL vials
54 Eppendorf tubes (0.5/1.5/2.0 mL) in 2 x 27 Eppendorf tube plate
Vial septa and closing mats must be pre-slit.
Carry-over< 0.1% with rinse factor > 3 (see test method listing in manual)